Total-Cross-Tied photovoltaic arrays with irregular configuration: a model

Authors

DOI:

https://doi.org/10.24054/rcta.v1i43.2821

Keywords:

Application example, calculation time reduction, implicit formulation, irregular photovoltaic array, Simulink/Matlab software

Abstract

Photovoltaic (PV) systems are extensively used in urban environments to produce electricity. Those PV installations are designed to take profit from unused spaces such as rooftops, where many other devices are installed (antenna, chimney, etc.), thus the available space is not regular. Therefore, a mathematical model must be designed to take into account those irregularities in the PV configuration. This paper introduces a new model for those irregular PV installations, which uses an implicit formulation of the current-voltage characteristic of the modules, thus avoiding costly mathematical computations like the lambert-W function to reduce the calculation time. The model is based on an equation system formulated from the circuital relations of the total cross tied structure, which is a suitable candidate for irregular PV installations. Finally, the model is validated using a realistic PV installation based on commercial PV modules.

Downloads

Download data is not yet available.

Author Biographies

Juan David Bastidas Rodríguez, Universidad Nacional de Colombia

Doctor en Ingeniería con énfasis en Ingeniería Eléctrica y Electrónica

Carlos Andrés Ramos Paja, Universidad Nacional de Colombia

Doctor en Ingeniería Electrónica, Automática y Comunicaciones

Andrés Julián Saavedra Montes, Universidad Nacional de Colombia

Doctor en Ingeniería Eléctrica

References

P. Frankl, “Energy System Debate: What Lies Ahead for the Future [In My View]”, IEEE Power and Energy Magazine, Vol. 17, No. 2, 2019, pp. 100-98.

Key, “Finding a bright spot”, IEEE Power and Energy Magazine, Vol. 7, No. 3, 2009, pp. 34-44.

G. Petrone, G. Spagnuolo, and M, Vitelli, “Analytical model of mismatched photovoltaic fields by means of Lambert W-function”, Solar Energy Materials and Solar Cells, Vol. 91, No. 18, 2007, pp. 1652–1657.

J. D. Bastidas-Rodriguez, C. A. Ramos-Paja, and A. J. Saavedra-Montes, “Implicit mathematical model of photovoltaic arrays with improved calculation speed based on inflection points of the current–voltage curves”, Energies, Vol. 16, No. 13, 2023, p. 4875.

R.M. Corless, G.H. Gonnet, D.E.G. Hare, D.J. Jeffrey, D.E. Knuth, “On the Lambert W function”, Advances in Computational Mathematics, Vol. 5, No. 1, 1996, pp 329–359.

J. Accarino, G. Petrone, C. A. Ramos-Paja and G. Spagnuolo, “Symbolic algebra for the calculation of the series and parallel resistances in PV module model”, 2013 International Conference on Clean Electrical Power (ICCEP), Alghero, Italy, 2013, pp. 62-66.

Published

2024-03-13 — Updated on 2024-03-13

Versions

How to Cite

Bastidas Rodríguez, J. D., Ramos Paja, C. A., & Saavedra Montes, A. J. (2024). Total-Cross-Tied photovoltaic arrays with irregular configuration: a model. COLOMBIAN JOURNAL OF ADVANCED TECHNOLOGIES, 1(43), 73–77. https://doi.org/10.24054/rcta.v1i43.2821